A simplified 1,10‐phenanthroline technique suitable for the determination of dissolved iron in remote sources of water

Date

1983-06-01

Journal Title

Journal ISSN

Volume Title

Publisher

Wiley

Abstract

A simple technique is described for the determination of dissolved iron in water. It is useful for investigating remote sources and avoids errors due to post‐sampling precipitation of hydrated ferric oxides. A small sample is added to a mixed 1.10‐phenanthroline‐i‐acetate buffer solution in the field and this‘developed sample” can then be stored for up to 4 weeks before the absorbancc value is read.

Description

Keywords

dissolved iron

Citation

Wright, R. C. (1983). A simplified 1,10‐phenanthroline technique suitable for the determination of dissolved iron in remote sources of water. Freshwater Biology, 13(3), 293–296. https://doi.org/10.1111/j.1365-2427.1983.tb00679.x